Deep sclerectomy with collagen implant: medium term results

AIMS—To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI), a new non-penetrating filtration procedure.
METHODS—Non-randomised prospective trial involving consecutive patients. 100 eyes of 100 patients with medically uncontrolled primary and secon...