CLINICAL EVALUATION OF THE LATEX FLOCCULATION TEST FOR PREGNANCY

Simultaneous pregnancy tests were run on duplicate specimens of urine by the Friedman method and the latex flocculation method on 329 patients. Clinical correlation was available in 245 of these patients. The latex test had a sensitivity of 77 per cent and a specificity of 92 per cent in the overall...