A carregar...

Problems associated with the EEA stapling technique for esophagojejunostomy after total gastrectomy.

Since November 1980, the EEA stapling device has been used to create an end-to-side esophagojejunostomy in 238 patients who underwent total gastrectomy. Failures in the stapling technique were divided into two groups: immediate and delayed. Immediate failures were observed and corrected at the time...