PTFE grafts for hemodialysis access. Techniques for insertion and management of complications.

In a series of 602 procedures, over 90% of primary forearm insertions of PTFE grafts between the radial artery and a cubital vein were possible. Thrombosis of the graft, which was invariably due to venous outflow obstruction, was the most common complication encountered. Revision of the venous anast...