Lataa...

An electromyographic method of objectively assessing cough intensity and use of the method to assess effects of codeine on the dose-response curve to citric acid.

The integrated surface abdominal electromyogram (EMG) has been used as a simple measurement of cough intensity which correlates well with the volume, air flow and noise produced in different coughs. Using the integrated abdominal EMG as a measure of cough intensity, dose response curves to inhaled c...

Täydet tiedot

Tallennettuna:
Bibliografiset tiedot
Päätekijät: Cox, I D, Wallis, P J, Apps, M C, Hughes, D T, Empey, D W, Osman, R C, Burke, C A
Aineistotyyppi: Artigo
Kieli:Inglês
Julkaistu: 1984
Aiheet:
Linkit:https://ncbi.nlm.nih.gov/pmc/articles/PMC1463642/
https://ncbi.nlm.nih.gov/pubmed/6487476
Tagit: Lisää tagi
Ei tageja, Lisää ensimmäinen tagi!