Comparison of digoxin and medigoxin in normal subjects.

1 The properties of a recently introduced digitalis glycoside, 4-beta-methyl digoxin (medigoxin) were compared to those of a standard digoxin preparation. Using a radioimmunoassay (RIA) technique, serial plasma levels were recorded for 8 h following a single oral dose in five fasting volunteer subje...