Wird geladen...

Charcoal haemoperfusion for paracetamol overdose

1 A controlled trial of charcoal haemoperfusion as an early treatment for paracetamol overdose showed no benefit. 2 The plasma clearances of paracetamol by the charcoal column were variable and disappointingly small (range 4-119 ml/minute). The cumulative amounts removed were also low, mean 1.4 g (r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gazzard, B. G., Willison, R. A., Weston, M. J., Thompson, R. P. H., Williams, R.
Format: Artigo
Sprache:Inglês
Veröffentlicht: 1974
Schlagworte:
Online Zugang:https://ncbi.nlm.nih.gov/pmc/articles/PMC1402556/
https://ncbi.nlm.nih.gov/pubmed/22454960
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!