Načítá se...

Use of Enzyme-Linked Immunospot Assay with Mycobacterium tuberculosis- Specific Peptides for Diagnosis of Recent Infection with M. tuberculosis after Accidental Laboratory Exposure

This report of an accidental exposure to Mycobacterium tuberculosis in a microbiological laboratory illustrates the value of gamma interferon enzyme-linked immunospot assay using peptides of ESAT-6, CFP-10, TB37.6, and TB7.7 for the diagnosis of latent infection. In particular, positive responses to...

Celý popis

Uloženo v:
Podrobná bibliografie
Hlavní autoři: Leyten, Eliane M. S., Mulder, Bert, Prins, Corine, Weldingh, Karin, Andersen, Peter, Ottenhoff, Tom H. M., van Dissel, Jaap T., Arend, Sandra M.
Médium: Artigo
Jazyk:Inglês
Vydáno: American Society for Microbiology 2006
Témata:
On-line přístup:https://ncbi.nlm.nih.gov/pmc/articles/PMC1393133/
https://ncbi.nlm.nih.gov/pubmed/16517931
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1128/JCM.44.3.1197-1201.2006