A Microsensor for Nitrate Based on Immobilized Denitrifying Bacteria

A biosensor for NO(inf3)(sup-) was constructed by attaching a 30- to 70-(mu)m-wide capillary with immobilized denitrifying bacteria in front of an N(inf2)O microsensor. These bacteria reduced O(inf2) so that only bacteria in the very tip of the sensor were exposed to O(inf2) whereas bacteria at a gr...

Celý popis

Uloženo v:
Podrobná bibliografie
Hlavní autoři: Larsen, L. H., Revsbech, N. P., Binnerup, S. J.