Direct Measurement of Potential Difference across the Human Red Blood Cell Membrane

The electrical potential difference across the human red cell membrane has been measured directly. A biological amplifier with neutralized input capacity was used. Human red cells in modified Ringer solution were impaled individually with 3 M KCl-filled glass microelectrodes. Movements of the microe...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Jay, A. W. L., Burton, A. C.
Formato: Artigo
Idioma:Inglês
Publicado em: 1969
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC1367420/
https://ncbi.nlm.nih.gov/pubmed/5764221