Fast, Triangular Voltage Clamp for Recording and Kinetic Analysis of an Ion Transporter Expressed in Xenopus Oocytes
We present a procedure for determination of 11 system parameters of an ion transporter expressed in Xenopus oocytes. The experiments consist of fast triangular voltage-clamp experiments in the presence and absence of external substrate. A four-state enzymatic cycle operating between an external and...