Analysis of Certain Errors in Squid Axon Voltage Clamp Measurements

Localized membrane current and potential measurements were made on the squid giant axon in voltage clamp experiments. Spatial control of potential was impaired by the use of axial current supplying electrodes with surface resistance greater than 20 ohms for a centimeter length of axon. No region of...