Effects of cellular geometry on current flow during a propagated action potential.
An impulse propagating in a cell with nonuniform geometry sees an increased electrical load at regions of increasing diameter or at branch points with certain morphologies. We present here theoretical and experimental studies on the changes in membrane current and axial current associated with diame...