Computer simulation of the effect of the nodal gap resistance on ionic current measurements in the Ranvier node membrane.

Results are presented of a computer simulation of the effect of the irreducible resistance introduced by the nodal gap, in series with the impedance of the axon membrane. A clamp potential is applied to a structure modeled as an electric circuit composed of a resistance in series with the membrane i...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Autori principali: Zaciu, C, Tripşa, M, Vasilescu, V
Natura: Artigo
Lingua:Inglês
Pubblicazione: 1981
Soggetti:
Accesso online:https://ncbi.nlm.nih.gov/pmc/articles/PMC1327660/
https://ncbi.nlm.nih.gov/pubmed/6976803