Measurement of potassium and chloride ion concentrations in the cupulae of the lateral lines of Xenopus laevis.

1. Potential measurements were made with double barrel ion selective electrodes from the cupulae of lateral line organs in the aquatic toad Xenopus laevis. 2. A positive endocupular potential (ECP) of 15-50 mV was recorded within the cupula, immediately above the hair cells. 3. Increases in the Cl-...