Compound action potentials recorded from mammalian peripheral nerves following ligation or resuturing.

1. Cat hind limb peripheral nerves were fitted with cuff recording electrodes, and their distal portions were later cut and ligated to prevent regeneration. The compound action potential amplitude initially declined with a time constant between 1 and 2 months and then remained relatively unchanged f...

תיאור מלא

שמור ב:
מידע ביבליוגרפי
Main Authors: Davis, L A, Gordon, T, Hoffer, J A, Jhamandas, J, Stein, R B
פורמט: Artigo
שפה:Inglês
יצא לאור: 1978
נושאים:
גישה מקוונת:https://ncbi.nlm.nih.gov/pmc/articles/PMC1281773/
https://ncbi.nlm.nih.gov/pubmed/370366