ロード中...
Aortic Thrombus after Coil Occlusion of a Type E Patent Ductus Arteriosus
A 5-year-old girl was referred to our institution for closure of a silent patent ductus arteriosus. Cardiac catheterization revealed a tiny-to-small patent ductus arteriosus of the elongated, conical type (Type E). Coil occlusion was performed with a Gianturco coil, 0.035-4 cm-3 mm. A follow-up echo...