Carregant...

Dose-response of acetylcholine receptor channels opened by a flash-activated agonist in voltage-clamped rat myoballs.

Whole-cell or single-channel currents through acetylcholine (ACh) receptor channels were studied in voltage-clamped rat myoballs or in excised membrane patches from myoballs. The recording pipette contained CsCl to suppress outward currents, and tetrodotoxin was used to help suppress Na+ currents. T...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autors principals: Chabala, L D, Gurney, A M, Lester, H A
Format: Artigo
Idioma:Inglês