Carregant...

Regulation of capillary blood flow and oxygen supply in skeletal muscle in dogs during hypoxaemia.

1. Multiwire surface electrodes were used to measure local hydrogen clearance curves and tissue PO2 in vivo. Evaluation of the initial slopes of the hydrogen clearance curves enabled the measurement of capillary blood flow and its distribution. 2. Capillary blood flow and tissue PO2 frequency distri...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autors principals: Harrison, D K, Kessler, M, Knauf, S K
Format: Artigo
Idioma:Inglês
Publicat: 1990
Matèries:
Accés en línia:https://ncbi.nlm.nih.gov/pmc/articles/PMC1190058/
https://ncbi.nlm.nih.gov/pubmed/2324992
Etiquetes: Afegir etiqueta
Sense etiquetes, Sigues el primer a etiquetar aquest registre!