Potassium-potassium exchange as part of the over-all reaction mechanism of the sodium pump of the human red blood cell.

When the efflux components of the Na-K exchange and K-K exchange are measured under identical conditions, the apparent K 1/2 (the concentration of K at which the velocity is half-maximal) for external K of the two processes differ. The discrepancy diminishes when the measurements are made in solutio...