Evaluation of the single radial haemolysis (SRH) technique for rubella antibody measurement.

Sera from 1258 individuals have been tested by four laboratories for rubella antibody by both the haemagglutination-inhibition and single radial haemolysis techniques. There was good agreement between the results obtained by the two methods. Although sheep red blood cells were used in the single rad...