Some clinically observed phenomena in extended contact lens wear.
Two groups of volunteer subjects wearing extended-wear soft lenses were monitored over a period of 20 weeks. Of 6 factors measured only 1, corneal touch threshold, was found to show evidence of progressive change. However, a high incidence of lens surface deposits was encountered.