Comparison of Snellen acuity, VER acuity, and Arden grating scores in macular and optic nerve diseases.
Patients with various macular and optic nerve abnormalities underwent Snellen acuity, transient VER acuity, and Arden grating testing. Snellen acuity was the coarsest of the 3 evaluations, generally falling after Arden scores and VER acuity had already undergone significant degradation. The Arden gr...