Axonal stimulation for end-plate jitter studies.

This single fibre EMG study compares the standard method of neuromuscular jitter measurement in voluntarily activated muscle to that by intramuscular electrical stimulation of motor axons in a group of normal subjects. The latter method avoids the interdischarge interval-dependent jitter, as well as...

Celý popis

Uloženo v:
Podrobná bibliografie
Hlavní autoři: Trontelj, J V, Mihelin, M, Fernandez, J M, Stålberg, E
Médium: Artigo
Jazyk:Inglês
Vydáno: 1986
Témata:
On-line přístup:https://ncbi.nlm.nih.gov/pmc/articles/PMC1028851/
https://ncbi.nlm.nih.gov/pubmed/3016197