Fatal aortic rupture during balloon dilatation of recoarctation.

In an eight year old boy with a patch aortoplasty, the aorta ruptured during balloon angioplasty for recoarctation. At necropsy a 1.5 cm long, full thickness tear and a separate, smaller, intimal tear were found. Histological examination showed thinning of the elastic laminae of the aorta. Angioplas...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Asıl Yazarlar: Balaji, S, Oommen, R, Rees, P G
Materyal Türü: Artigo
Dil:Inglês
Baskı/Yayın Bilgisi: 1991
Konular:
Online Erişim:https://ncbi.nlm.nih.gov/pmc/articles/PMC1024501/
https://ncbi.nlm.nih.gov/pubmed/1831032