Improving Hemostasis during Replacement of the Ascending Aorta and Aortic Valve with a Composite Graft

The use of a composite graft is an established treatment for patients with aortic valve disease and ascending aortic aneurysms. Since bleeding from suture lines is a potential complication of this procedure, we modified the technique and evaluated the effect on hemostasis. From January 1994 through...