N-N-dimethylformamide concentration in environmental and alveolar air in an artificial leather factory.

N-N-Dimethylformamide was determined every hour during the eight hours of the work shift in the alveolar air of eight workers employed in an artificial leather factory and in the breathing zone of the eight workers. The alveolar ventilation of each worker was measured for 10 minutes during the work...