Načítá se...

Monte Carlo Simulations of Neutron Ambient Dose Equivalent in a Novel Proton Therapy Facility Design

Purpose: The neutron shielding properties of the concrete structures of a proposed proton therapy facility were evaluated with help of the Monte Carlo technique. The planned facility’s design omits the typical maze-structured entrances to the treatment rooms to facilitate more efficient access and,...

Celý popis

Uloženo v:
Podrobná bibliografie
Hlavní autoři: Uwe Titt, Enzo Pera, Michael T. Gillin
Médium: Artigo
Jazyk:Inglês
Vydáno: Particle Therapy Co-operative Group 2020-03-01
Edice:International Journal of Particle Therapy
Témata:
On-line přístup:https://theijpt.org/doi/pdf/10.14338/IJPT-19-00071.1
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo otaguje tento záznam!