Failure Analysis of Transmission Tower in Full-Scale Tests
With the rapid development of Ultra-High Voltage (UHV) transmission lines, it is necessary to study the performance of UHV transmission towers. First, we performed full-scale tests on a transmission tower under seven loading patterns. Then, the test results were compared with the calculation results...