Numerical Study on Improved Baffle in Compact Test Separator

The aim of this paper is to design two improved baffles to solve the injection problem caused by traditional baffle in compact test separatorand use FLUENT software to study their effects on separator pressure loss and separation efficiency. The result shows: that anti-injection baffle can make comp...