DUSTY ENVIRONMENT IMPACT ON LIFESPAN OF THE INDUCTION MOTORS STATOR WINDING
Large quantity of asynchronous motors work in heavily dusted environments. On the end-winding insulation of the motors to 55 kW operating in the mining and smelting enterprise there is a 3 cm dust layer, which may lead to the asynchronous motor end-winding local overheat and consequent early breakdo...