Gas Hold-Up in Vessel with Dual Impellers and Different Baffles
The influence of impellers system, baffles system and type of liquid on gas hold-up in a vessel has been presented in this paper. The analysis of gas hold-up was conducted on the basis of the data obtained in the vessel. The vessel used in the study was of inner diameter <i>D</i> = 0.288 m, and it w...