Equipment Optimization Scheme for High Failure Rate Auxiliary Converter of Metro Train in High Temperature and High Humidity Environment

Objective Over high humidity in the operating environment of metro train auxiliary power supply system will lead to high leakage current of IGBT (insulated gate bipolar transistor), which may further cause the auxiliary converter failure. Therefore, it is necessary to optimize the internal environme...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Autori principali: HUANG Huijian, FAN Yijun, SU Hanchong, HUANG Xing, PU Anhui, HE Hongli
Natura: Artigo
Lingua:Chinês
Pubblicazione: Urban Mass Transit Magazine Press 2024-09-01
Serie:Chengshi guidao jiaotong yanjiu
Soggetti:
Accesso online:https://umt1998.tongji.edu.cn/journal/paper/doi/10.16037/j.1007-869x.2024.09.045.html