Oscillation of a Liquid Column in an Eccentric Annulus
The velocity distribution of flow in an eccentric cylindrical annulus is determined in an attempt to investigate the vertical capillary rise in the channel. The critical values of the radii ratio and the eccentricity at which the capillary rise changes from oscillatory to monotone or vice versa are...
Gorde:
| Egile nagusia: | |
|---|---|
| Formatua: | Artigo |
| Hizkuntza: | Inglês |
| Argitaratua: |
MDPI AG
2024-08-01
|
| Saila: | Fluids |
| Gaiak: | |
| Sarrera elektronikoa: | https://www.mdpi.com/2311-5521/9/8/189 |
| Etiketak: |
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
|