IGBT Real-time Junction Temperature Calculation Based on Converter Operation Data

In order to evaluate IGBT operation junction temperature of locomotive operation and provide the basis for IGBT health status and life prediction, a real-time junction temperature calculation method was proposed based on the average power loss of each fundamental period from output phase voltage and...