Incidence of postdural puncture headache: Two different fine gauge spinal needles of the same diameter
Objective: The aim of this study was to compare two spinal needles with different bevel designs regarding their technical handling capacities and complication rates. Materials and Methods: After the clinical trials Ethics Committee approval and informed consents from the patients, 220 pregnant femal...
Salvato in:
| Autori principali: | , , , , |
|---|---|
| Natura: | Artigo |
| Lingua: | Inglês |
| Pubblicazione: |
Wolters Kluwer Medknow Publications
2014-01-01
|
| Serie: | Journal of Obstetric Anaesthesia and Critical Care |
| Soggetti: | |
| Accesso online: | http://www.joacc.com/article.asp?issn=2249-4472;year=2014;volume=4;issue=2;spage=64;epage=68;aulast=Abdullayev |