Treatment of a Gustilo-Anderson type II open tibia shaft fracture with an ultrathin silver plasma-coated plate: A case report

The treatment of open tibia fractures with plate fixation bears a high risk for the development of a fracture-related infection. Here we present a case of an 80-year-old female with a Gustilo-Anderson type II open distal tibial shaft fracture with an indwelling knee prosthesis. The case was successf...