Dynamic digital radiography is a valid and reliable alternative to 3 Dimensional registration for scapulohumeral rhythm analysis

Background: Scapulohumeral rhythm (SHR) is a key metric for evaluating shoulder joint function. Current established methods of SHR analysis involve 3-dimensional (3D) to 2-dimensional (2D) registration, which requires significantly greater resources to generate dynamic positioning data of the humeru...