PRESSURE AND PRESSURE DERIVATIVE ANALYSIS FOR INJECTION TESTS WITH VARIABLE TEMPERATURE WITHOUT TYPE-CURVE MATCHING ANÁLISIS DE PRESIÓN Y DERIVADA DE PRESIÓN EN PRUEBAS DE INYECCIÓN CON TEMPERATURA VARIABLE SIN EMPLEAR CURVAS TIPO

The analysis of injection tests under nonisothermic conditions is important for the accurate estimation of the reservoir permeability and the well's skin factor; since previously an isothermical system was assumed without taking into account a moving temperature front which expands with time plus th...

Ausführliche Beschreibung

Gespeichert in:
Bibliografische Detailangaben
Hauptverfasser: Freddy-Humberto Escobar, Javier-Andrés Martínez, Matilde Montealegre-M.
Format: Artigo
Sprache:Inglês
Veröffentlicht: Instituto Colombiano del petróleo y energías de la Transición - ICPET 2008-12-01
Schriftenreihe:CT&F Ciencia, Tecnología & Futuro
Schlagworte:
Online-Zugang:http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0122-53832008000100006