On the Operational Conditions’ Effect on the Performance of an Anion Exchange Membrane Water Electrolyzer: Electrochemical Impedance Spectroscopy Study
The performance of an anion exchange membrane water electrolyzer under various operational conditions (including voltage, KOH-supporting electrolyte concentration, and flow rate) is studied using conventional time-domain technics and electrochemical impedance spectroscopy (EIS). The water electrolyz...