QR kód

Computational Analysis of Tube Wall Temperature of Superheater in 1000 MW Ultra-Supercritical Boiler Based on the Inlet Thermal Deviation

Local over-temperature is one of the main reasons for boiler tube failures (BTF). By accurately monitoring and controlling tube wall temperature, local over-temperature can be avoided. Based on the measured flue gas parameters and numerical simulation, a method of thermal deviation calculation is pr...

Celý popis

Uloženo v:
Podrobná bibliografie
Hlavní autoři: Pei Li, Ting Bao, Jian Guan, Zifu Shi, Zengxiao Xie, Yonggang Zhou, Wei Zhong
Médium: Artigo
Jazyk:Inglês
Vydáno: MDPI AG 2023-02-01
Edice:Energies
Témata:
On-line přístup:https://www.mdpi.com/1996-1073/16/3/1539
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!