Practical and Reliable Methanol Concentration Sensor for Direct Methanol Fuel Cells
An electrochemical methanol concentration sensor with practicality and reliability has been developed to apply for a direct methanol fuel cell (DMFC) system. The methanol concentration can be estimated simply by the original algorithm based on the Arrhenius law and diffusion limiting current, even t...