Codice QR

SENSORLESS FLUX REGION MODIFICATION OF DTC CONTROLLED IM FOR TORQUE RIPPLE REDUCTION

A Direct Torque Control (DTC) drive allows direct and independent control of flux linkage and electromagnetic torque by the selection of optimum inverter switching tables. There is no need for any complex transformation of current or voltage. However, each vector selected from the switching table ca...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Autori principali: Yavuz USER, Kayhan GULEZ, Sukru OZEN
Natura: Artigo
Lingua:Inglês
Pubblicazione: İstanbul University-Cerrahpasa 2014-09-01
Serie:Electrica
Soggetti:
Accesso online:https://www.electricajournal.org/index.php/pub/article/view/583