Reversed phase HPLC for strontium ranelate: Method development and validation applying experimental design
A reverse-phase HPLC (RP-HPLC) method was developed for strontium ranelate using a full factorial, screening experimental design. The analytical procedure was validated according to international guidelines for linearity, selectivity, sensitivity, accuracy and precision. A separate experimental desi...
Сохранить в:
| Главные авторы: | , , , , , , , |
|---|---|
| Формат: | Artigo |
| Язык: | Inglês |
| Опубликовано: |
Sciendo
2018-06-01
|
| Серии: | Acta Pharmaceutica |
| Предметы: | |
| Online-ссылка: | https://doi.org/10.2478/acph-2018-0019 |
| Метки: |
Нет меток, Требуется 1-ая метка записи!
|