Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is succes...

Celý popis

Uloženo v:
Podrobná bibliografie
Hlavní autor: Afshin Hedayat
Médium: Artigo
Jazyk:Inglês
Vydáno: Elsevier 2017-08-01
Edice:Nuclear Engineering and Technology
Témata:
On-line přístup:http://www.sciencedirect.com/science/article/pii/S1738573317302413