Código QR

Comparison of Serum Spec fPL™ and 1,2‐o‐Dilauryl‐Rac‐Glycero‐3‐Glutaric Acid‐(6′‐Methylresorufin) Ester Assay in 60 Cats Using Standardized Assessment of Pancreatic Histology

Background Feline pancreas‐specific lipase (Spec fPL) is considered a useful test for the antemortem diagnosis of pancreatitis in cats. A recent study found good agreement between the results of the Spec fPL and catalytic 1,2‐o‐dilauryl‐rac‐glycero‐3‐glutaric acid‐(6′‐methylresorufin) ester (DGGR) l...

Descrición completa

Gardado en:
Detalles Bibliográficos
Principais autores: S. Oppliger, M. Hilbe, S. Hartnack, E. Zini, C.E. Reusch, P.H. Kook
Formato: Artigo
Idioma:Inglês
Publicado: Oxford University Press 2016-05-01
Series:Journal of Veterinary Internal Medicine
Assuntos:
Acceso en liña:https://doi.org/10.1111/jvim.13924