Required number of self‐drilling screws for built‐up column comprising cold‐formed lipped channel sections to ensure flexural buckling as a single unit member
Abstract This study analyzed the flexural buckling behavior of light‐gauge built‐up compression members joined by self‐drilling screws by using the energy method. A nonconventional mechanical model that simulates the flexural buckling behavior of a built‐up member was proposed, and the contradiction...