CORROSION OF AIR PREHEATER TUBES OF OIL SHALE CFB BOILER. PART I. DEW POINT OF FLUE GAS AND LOW-TEMPERATURE CORROSION; pp. 5–12

The damage to air preheater (APH) tubes in the zones where air and gas temperatures are low discovered in CFB boilers at Estonian oil shale power plants was indicative of low-temperature corrosion (LTC). To establish damage causes, samples of ash deposits from boiler heating surfaces and APH corrode...