QR Kodea

Detailed reproduction of the neutron emission from the compact DT neutron generator used as an in-situ 14 MeV calibration neutron source at JET

A compact DT neutron generator (NG) based on the mixed-beam operation was used as a calibration neutron source in the latest in-situ calibration of neutron detectors at the Joint European Torus (JET). In order to meet the requirement for the total uncertainty of the neutron detector calibration belo...

Deskribapen osoa

Gorde:
Xehetasun bibliografikoak
Egile Nagusiak: Čufar Aljaž, Batistoni Paola, Ghani Zamir, Giacomelli Luca, Lengar Igor, Loreti Stefano, Milocco Alberto, Popovichev Sergey, Pillon Mario, Rigamonti Davide, Rebai Marica, Tardocchi Marco, Snoj Luka
Formatua: Artigo
Hizkuntza:Inglês
Argitaratua: EDP Sciences 2020-01-01
Saila:EPJ Web of Conferences
Gaiak:
Sarrera elektronikoa:https://www.epj-conferences.org/articles/epjconf/pdf/2020/01/epjconf_animma2019_02005.pdf