Effect of 600 MW Supercritical Steam Turbine Prolonging Running Time of Mixing Valve on Unit Vibration

The bearing vibration of No.2, No.3, No.4, No.5, No.6 of a 600 MW supercritical steam turbine in a power plant is relatively large. In order to solve this problem, the intake mode of the steam turbine was changed by prolonging the operation time of the mixing valve with the initial load to make the...